Method Name
A short description of the method used to perform the test
PCR and Direct DNA Sequencing
NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.
Yes
Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test
HLA B High Resolution
Aliases
Lists additional common names for a test, as an aid in searching
DNA Sequencing HLA B
Sequencing HLA B High Resolution Typing
Specimen Type
Describes the specimen type validated for testing
Whole Blood EDTA
Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing
Histocompatibility Lab Transplant Testing Requisition is required.
Draw blood in a lavender-top (EDTA) tube(s).
Send 14 mL of EDTA whole blood at ambient temperature.
Special Instructions
Library of PDFs including pertinent information and forms related to the test
Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.
Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected
Specimen Type |
Temperature |
Time |
Special Container |
Whole Blood EDTA |
Ambient |
14 days |
|
Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.
Testing is complete. Final report has been sent to the referring laboratory.
Fees :
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.
- Authorized users can sign in to Test Prices for detailed fee information.
- Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
- Prospective clients should contact their account representative. For assistance, contact Customer Service.
Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.
This test was developed and its performance characteristics determined by Versiti Wisconsin, Inc. It has not been cleared or approved by the US Food and Drug Administration. This test is used for clinical purposes. It should not be regarded as investigational or for research. This laboratory is certified under the Clinical Laboratory Improvement Amendments (CLIA) as qualified to perform high complexity clinical laboratory testing.
Test Id |
Test Order Name |
Order LOINC Value
|
FHLAB |
HLA B High Resolution |
45028-8 |
Result Id |
Test Result Name |
Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
|
Z0130 |
HLA B High Resolution |
45028-8 |
Z0119 |
Comments: |
48767-8 |