Quantitative Sandwich Enzyme Immunoassay (EIA)
Histoplasma capsulatum Antigen
Histoplasma Polysaccharide Antigen
CSF
Specimen Type: Spinal Fluid
Sources: CSF
Container/Tube: Sterile container
Specimen Volume: 0.8 mL
Collection Instructions: Collect 0.8 mL of spinal fluid (CSF). Ship refrigerated, 0.8 mL of spinal fluid. Send specimen in a plastic, screw-capped vial refrigerated.
0.8 mL
Other | Specimen that is too viscous to pipette. Tissue, biopsy, sputum, bronchial brush, tracheal aspirate, FNA, bone marrow aspirate, stool or samples in transport media, fixative or Isolator tubes |
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
CSF | Refrigerated (preferred) | 14 days | |
Ambient | 14 days | ||
Frozen |
Reference interval: None Detected
Reportable Range: Positive Results reported in ng/mL from 0.20 ng/mL to 20.00 ng/mL.
Positive Results above 20.00 ng/mL are reported as “Above the Limit of Quantification”.
Cross-reactions are seen with blastomycosis, paracoccidioidomycosis, penicilliosis, less frequently in coccidioidomycosis, rarely in aspergillosis and possibly sporotrichosis.
Sputolysin, sodium hydroxide and potassium hydroxide treatment degrade the analyte detected in the assay.
Monday through Friday
This test was developed and its performance characteristics determined by MiraVista Diagnostics. It has not been cleared or approved by the FDA; however, FDA clearance or approval is not currently required for clinical use. The results are not intended to be used as the sole means for clinical diagnosis or patient management decisions.
87385
Test Id | Test Order Name | Order LOINC Value |
---|---|---|
FHSAG | MVista Histoplasma Ag, CSF | 51754-0 |
Result Id | Test Result Name |
Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
|
---|---|---|
Z1722 | Result: | 51754-0 |
Z1034 | Interpretation | Not Provided |
Change Type | Effective Date |
---|---|
Test Changes - Specimen Information | 2023-03-03 |