Test Catalog

Test Id : FANIC

Anti-Nuclear Antibodies by Indirect Fluorescent Antibody (IFA), Cerebrospinal Fluid

Useful For
Suggests clinical disorders or settings where the test may be helpful

ANA are commonly found in a variety of autoimmune diseases. Antibody frequency increases with age in apparently healthy people. ANA patterns on Hep-2 slides provide only general clues about particles (chromatin, nucleosomes and spliceosomes). ANA patterns (other than centromere pattern) are not reliably correlated with the presence of specific antibodies and must be further evaluated by EIA using individual ENA antigens.

Reflex Tests
Lists tests that may or may not be performed, at an additional charge, depending on the result and interpretation of the initial tests.

Test Id Reporting Name Available Separately Always Performed
FANTC ANA Titer and Pattern CSF No No

Method Name
A short description of the method used to perform the test

Indirect Fluorescent Antibody (IFA)

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

ANA by IFA, CSF

Specimen Type
Describes the specimen type validated for testing

CSF

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Specimen Type: Cerebrospinal fluid (CSF)

Collection Container/Tube: Sterile container

Submission Container/Tube: Plastic vial

Specimen Volume: 2 mL

Collection Instructions: Collect cerebrospinal fluid (CSF) in a sterile container and ship refrigerate.

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.

0.5 mL (Note: this volume does NOT allow for repeat testing)

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Gross hemolysis: Reject
Thawing: Warm OK; Cold OK
Gross lipemia: Reject
Gross icterus Reject
Other: Bacterial contamination, Anything other than CSF

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
CSF Refrigerated (preferred) 14 days
Frozen 60 days
Ambient 7 days

Useful For
Suggests clinical disorders or settings where the test may be helpful

ANA are commonly found in a variety of autoimmune diseases. Antibody frequency increases with age in apparently healthy people. ANA patterns on Hep-2 slides provide only general clues about particles (chromatin, nucleosomes and spliceosomes). ANA patterns (other than centromere pattern) are not reliably correlated with the presence of specific antibodies and must be further evaluated by EIA using individual ENA antigens.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

ANA by IFA, CSF: Negative

ANA Pattern: No Pattern

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday-Friday

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Esoterix Endocrinology

Fees :
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

86038

86039 (if appropriate)

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
FANIC ANA by IFA, CSF 63294-3
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
FANIC ANA by IFA, CSF 63294-3

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports