High Performance Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)
Invega
Serum Red
***Must submit one specimen per order. Specimens cannot be shared between multiple orders.***
Specimen Type: Serum
Specimen Volume: 1 mL
Collection Instructions: Draw blood in a plain, red-top tube(s). (Serum gel tube is not acceptable.) Spin down and send 1 mL of serum refrigerate in a preservative-free plastic vial.
0.5 mL
Other | Polymer gel separation tube (SST or PST) |
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum Red | Refrigerated (preferred) | 14 days | |
Ambient | 14 days | ||
Frozen |
None Detected ng/mL
Units: ng/mL
Paliperidone is an atypically-structured antipsychotic agent and the main pharmacologically active metabolite of Risperidone (commonly referred to as 9-hydroxyrisperidone).
The following mean plasma paliperidone concentrations have been reported:
3 mg single extended release oral dose: 4.9 ng/mL at 24 hours
6 mg single extended release oral dose: 10 ng/mL at 24 hours
12 mg single extended release oral dose: 20 ng/mL at 24 hours
3 mg extended release oral dose for 7 days: 11 ng/mL at 22 hours after last dose
78-156 mg IM once monthly for 6 months: 10-20 ng/mL (median trough concentration)
Acute ingestion of 180 and 504 mg extended release paliperidone resulted in serum concentrations of 170 and 883 ng/mL, respectively, approximately 40 hours after ingestion and the reported serum concentration following acute ingestion of 270 mg was 100 ng/mL 16 hours post-ingestion.
A femoral blood paliperidone concentration of 240 ng/mL was the only finding in an individual who died 2 weeks after a 525 depot IM injection.
The blood/plasma ratio of paliperidone is 0.7-0.8.
Monday - Sunday
This test was developed and its performance characteristics determined by NMS Labs. It has not been cleared or approved by the U.S. Food and Drug Administration.