Test Catalog

Test Id : JIP

Joint Infection Panel, PCR, Synovial Fluid

Useful For
Suggests clinical disorders or settings where the test may be helpful

Rapid detection of synovial fluid infections caused by the following:

Anaerococcus prevotii/vaginalis

Finegoldia magna

Streptococcus species

Clostridium perfringens

Parvimonas micra

Streptococcus agalactiae

Cutibacterium avidum/granulosum

Peptoniphilus species

Streptococcus pneumoniae

Enterococcus faecalis

Peptostreptococcus anaerobius

Streptococcus pyogenes

Enterococcus faecium

Staphylococcus aureus

Staphylococcus lugdunensis

Bacteroides fragilis

Kingella kingae

Proteus species

Citrobacter species

Klebsiella aerogenes

Pseudomonas aeruginosa

Enterobacter cloacae complex

Klebsiella pneumoniae complex

Salmonella species

Escherichia coli

Morganella morganii

Serratia marcescens

Haemophilus influenzae

Neisseria gonorrhoeae

Candida species

Candida albicans

 

This test is not recommended as a test of cure.

Highlights

The BIOFIRE Joint Infection (JI) Panel is a multiplexed nucleic-acid-based, in vitro diagnostic test for the simultaneous qualitative detection and identification of 31 bacterial and yeast nucleic acids and 8 antimicrobial resistance genes from synovial fluid obtained from individuals suspected to have a JI.

 

This test is used to diagnose infections caused by Anaerococcus prevotii/vaginalis, Finegoldia magna, Streptococcus species., Clostridium perfringens, Parvimonas micra, Streptococcus agalactiae, Cutibacterium avidum/granulosum, Peptoniphilus, Streptococcus pneumoniae, Enterococcus faecalis, Peptostreptococcus anaerobius, Streptococcus pyogenes, Enterococcus faecium, Staphylococcus aureus, Staphylococcus lugdunensis, Bacteroides fragilis, Kingella kingae, Proteus species., Citrobacter, Klebsiella aerogenes, Pseudomonas aeruginosa, Enterobacter cloacae complex, Klebsiella pneumoniae group, Salmonella species., Escherichia coli, Morganella morganii, Serratia marcescens, Haemophilus influenzae, Neisseria gonorrhoeae, Candida species., and Candida albicans.

 

The test can also detect the following antimicrobial resistance genes: CTX-M, KPC, NDM, vanA/B, IMP, mecA/C and MREJ (MRSA), OXA-48-like, and VIM.

Method Name
A short description of the method used to perform the test

Multiplex Polymerase Chain Reaction (PCR)

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Joint Infect Panel PCR, Synovial Fl

Aliases
Lists additional common names for a test, as an aid in searching

Anaerococcus prevotii/vaginalis

Finegoldia magna

Streptococcus species

Clostridium perfringens

Parvimonas micra

Streptococcus agalactiae

Cutibacterium avidum/granulosum

Peptoniphilus species

Streptococcus pneumoniae

Enterococcus faecalis

Peptostreptococcus anaerobius

Streptococcus pyogenes

Enterococcus faecium

Staphylococcus aureus

Staphylococcus lugdunensis

Bacteroides fragilis

Kingella kingae

Proteus species

Citrobacter species

Klebsiella aerogenes

Pseudomonas aeruginosa

Enterobacter cloacae complex

Klebsiella pneumoniae complex

Salmonella species

Escherichia coli

Morganella morganii

Serratia marcescens

Haemophilus influenzae

Neisseria gonorrhoeae

Candida species

Candida albicans

abc

Specimen Type
Describes the specimen type validated for testing

Synovial Fluid

Ordering Guidance

This test is appropriate for raw, unprocessed, and untreated synovial fluid specimens only.

Shipping Instructions

Specimen must arrive at refrigerated temperature within 7 days of collection.

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Specimen Type: Synovial fluid

Container/Tube: Sterile vial

Specimen Volume: 1 mL

Collection Instructions:

1. Do not process or treat sample in any way.

2. Label specimen as synovial fluid.

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.

0.5 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Specimen in anaerobe vial or viral transport medium (including but not limited to M4, M5, BD viral transport media, thioglycolate broth)
Any specimen that has been centrifuged
Anticoagulant or additive
Swabs (any type or transport system)
Reject

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Synovial Fluid Refrigerated (preferred) 7 days
Ambient 4 hours

Useful For
Suggests clinical disorders or settings where the test may be helpful

Rapid detection of synovial fluid infections caused by the following:

Anaerococcus prevotii/vaginalis

Finegoldia magna

Streptococcus species

Clostridium perfringens

Parvimonas micra

Streptococcus agalactiae

Cutibacterium avidum/granulosum

Peptoniphilus species

Streptococcus pneumoniae

Enterococcus faecalis

Peptostreptococcus anaerobius

Streptococcus pyogenes

Enterococcus faecium

Staphylococcus aureus

Staphylococcus lugdunensis

Bacteroides fragilis

Kingella kingae

Proteus species

Citrobacter species

Klebsiella aerogenes

Pseudomonas aeruginosa

Enterobacter cloacae complex

Klebsiella pneumoniae complex

Salmonella species

Escherichia coli

Morganella morganii

Serratia marcescens

Haemophilus influenzae

Neisseria gonorrhoeae

Candida species

Candida albicans

 

This test is not recommended as a test of cure.

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Joint infections (JI) occur when pathogens access bones and joints via hematogenous spread, contiguous spread of pathogens from an adjacent infection, or direct implantation (eg, open fracture, surgery, implanted medical devices). JI broadly encompasses multiple types of infections including, but not limited to, septic arthritis (SA), and prosthetic joint infection (PJI). These infections are commonly diagnosed by a combination of laboratory results, microbiological data, histological evaluation of tissue, intraoperative inspection, and in some cases radiographic results.(1) JI are most often caused by bacterial pathogens, though yeasts are also a significant cause. Serious morbidity can arise from JI, resulting in significant pain, permanent disability, or death.(2) Additionally, JI are often complicated and result in increased hospital stay length as well as higher rates of long-term rehabilitation and rehospitalization.(3,4) Globally, the prevalence of JI is estimated to be four to ten per 100,000 people in developed countries, with the economic impact of such infections totaling hundreds of millions of dollars per year.(4,5)

 

Timely diagnosis of JI and administration of effective treatment can significantly reduce the rates of serious complications, duration of hospital stays, and costs. The BIOFIRE JI Panel tests a single synovial fluid sample to simultaneously provide results for multiple aerobic and anaerobic bacteria and yeast that cause JI as well as genetic markers associated with antimicrobial resistance. Although JI is a broad category that includes multiple types of infections, the BIOFIRE JI Panel was primarily designed to detect organisms associated with SA and PJI. Rapid identification of the organism(s) in synovial fluid, along with information about antimicrobial resistance gene status for select microorganisms, may aid the physician in making timely and appropriate treatment and management decisions.

 

The BIOFIRE JI Panel is indicated as an aid in the diagnosis of specific agents of JI and results should be used in conjunction with other clinical and laboratory findings. Negative results may be due to infection with pathogens that are not detected by this test, pathogens present below the limit of detection of the assay, or infection that may not be detected in a synovial fluid specimen. Positive results do not rule out co-infection with other organisms. The BIOFIRE JI Panel is not intended to monitor treatment for JI.

 

Culture of synovial fluid is necessary to recover organisms for susceptibility testing and epidemiological typing, to identify organisms in the synovial fluid that are not detected by the BIOFIRE JI Panel, and to further identify species in the genus, complex, or group results.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Undetected

Interpretation
Provides information to assist in interpretation of the test results

Results are intended to aid in the diagnosis of illness and are meant to be used in conjunction with other clinical and epidemiological findings.

 

Detected results do not distinguish between a viable or replicating organism and a nonviable organism or nucleic acid, nor do they exclude the potential for coinfection by organisms not included in the panel.

 

Negative results do not exclude the possibility of infection and should not be used as the sole basis for diagnosis, treatment, or other management decisions.

 

The antimicrobial resistance genes detected may or may not be associated with the agents responsible for disease. Undetected results for the included antimicrobial resistance genes do not guarantee susceptibility to corresponding classes of antimicrobials, as other mechanisms of antimicrobial resistance exist.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

The detection of bacterial, yeast, and antimicrobial resistance gene nucleic acid is dependent upon proper sample collection, handling, transportation, and storage. Failure to observe proper procedures in any one of these steps can lead to incorrect results. There is a risk of false positive or false negative results from improperly collected, transported, or handled samples.

 

Negative results do not exclude the possibility of infection and should not be used as the sole basis for diagnosis, treatment, or other management decisions. Negative results may be due to infection with organism(s) not identified by the BIOFIRE Joint Infection (JI) Panel or due to an organism concentration in the sample that is below the limit of detection for the test. Organism levels may be influenced by concurrent antibacterial/antifungal therapy, which could lead to organism levels below the limit of detection for the test.

 

The BIOFIRE JI Panel is intended to be used in conjunction with clinical history, signs and symptoms, and results of other diagnostic tests, including culture and anti-microbial susceptibility testing.

 

The BIOFIRE JI Panel has not been validated for testing of specimens other than synovial fluid specimens.

 

The BIOFIRE JI Panel is not intended for use with synovial fluid in media. Media/broths may contain contaminating nucleic acids that can generate false positives.

 

The performance of BIOFIRE JI Panel has not been established for specimens collected from individuals without signs or symptoms of a JI.

 

The performance of the BIOFIRE JI Panel has not been specifically evaluated for synovial fluid specimens collected from patients being treated with antibiotics.

 

Bacterial and yeast nucleic acids may persist in vivo independent of organism viability. Detection of organism nucleic acid does not imply that the corresponding organisms are infectious or are the causative agents for clinical symptoms.

 

The results for the antimicrobial resistance gene assays do not specifically link the resistance gene to the applicable bacteria detected. In polymicrobial specimens, the resistance gene may be associated with any of the applicable bacteria detected or an organism that was not detected by the panel.

 

Antimicrobial resistance can occur via multiple mechanisms. A "Not Detected" result for the antimicrobial resistance gene assays does not indicate antimicrobial susceptibility. Subculturing and standard susceptibility testing of isolates are required to determine antimicrobial susceptibility.

Supportive Data

This test is US Food and Drug Administration approved on synovial fluid specimens; the manufacturer has evaluated the clinical performance data of this sample type. The Clinical Bacteriology Laboratory at Mayo Clinic conducted a verification of the FilmArray Joint Infection Panel using 5 pools of known target analytes from a commercially available verification panel. The assay demonstrated overall agreement of 100% with expected results. The Clinical Bacteriology Laboratory also compared culture growth of 75 clinical samples (42 positive and 33 negative) and JIP results. The percent positive agreement was above 80% for all targets tested. The pools did not include the downgraded organism identifications for the Streptococcus species and Candida species but were included in the clinical specimens tested.

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Tande AJ, Patel R. Prosthetic Join Infection. Clin Micrbiol Rev. 2014;27(2):302-345. doi:10.1128/CMR.00111-13

2. Berendt T, Byren I. Bone and joint infection. Clin Med (Lond). 2004;4(6):510-518. doi:10.7861/clinmedicine.4-6-510

3. Lipsky BA, Weigelt JA, Gupta V, Killian A, Peng MM. Skin, Soft Tissue, Bone, and Joint Infections in Hospitalized Patients: Epidemiology and Microbiological, Clinical, and Economic Outcomes. Infect Control Hosp Epidemiol. 2007;28(11):1290-1298. doi:10.1086/520743

4. Grammatico-Guillon L, Baron S, Gettner S, et al. Bone and joint infections in hospitalized patients in France, 2008: clinical and economic outcomes. J Hosp Infect. 2012;82(1):40-48. doi:10.1016/j.jhin.2012.04.025

5. Faust SN, Clark J, Pallett A, Clarke NMP. Managing bone and joint infection in children. Arch Dis Child. 2012;97(6):545-553. doi:10.1136/archdischild-2011-301089

6. Esteban J, Salar-Vidal L, Schmitt BH. Multicenter evaluation of the BIOFIRE Joint Infection Panel for the detection of bacteria, yeast, and AMR genes in synovial fluid samples. J Clin Microbiol. 2023;61(11):e0035723. doi:10.1128/jcm.00357-23

Method Description
Describes how the test is performed and provides a method-specific reference

The BIOFIRE Joint Infection Panel is a closed system that performs all the chemistry required to isolate, amplify, and detect nucleic acid from multiple bacterial, yeast, and select antimicrobial resistance genes from synovial fluid obtained from individuals suspected to have a joint infection. A panel contains reagents in freeze-dried form and is divided into discrete segments where the required chemical processes are carried out. Patient sample and hydration fluid are drawn by vacuum into the panel and then placed into the Biofire FilmArray instrument. The detection process operations are automated (nucleic acid purification, first stage polymerase chain reaction (PCR), second stage PCR, and melt curve analysis of replicates for each assay) and complete in about an hour in this closed system.

 

Nucleic Acid Purification:

The sample is lysed by a combination of chemical and mechanical mechanisms, and the liberated nucleic acid is captured, washed, and eluted using magnetic bead technology.

 

First-Stage PCR:

A reverse transcription step is performed to convert viral RNA into complementary DNA prior to amplification. The purified nucleic acid solution is combined with a preheated master mix to initiate the reverse transcription step and subsequent thermocycling for multiplex PCR.

 

Second-Stage PCR:

Products of first stage PCR are diluted and mixed with fresh PCR reagents, which is distributed over the second stage PCR array. The individual wells of the array contain primers for different assays (in triplicate) that target specific nucleic acid sequences from each of the pathogens detected, as well as control template material.

 

DNA Melting Analysis:

Temperature is slowly increased, and fluorescence in each well of the array is monitored and analyzed to generate a melt curve.

 

Analysis of Melt Curves:

The software evaluates the DNA melt curve for each well to determine if a PCR product was present in that well. If the melt profile indicates the presence of a PCR product, then the analysis software calculates the melting temperature of the curve, which is then compared against the expected range for the assay. When the software determines that the melt curve falls inside the assay-specific melt temp range, it is called positive. When it determines that the melt curve is not in the appropriate range, it is called negative.

 

Analysis of Replicates:

Melt curves of each of the 3 replicates for each assay are evaluated to determine the assay result. For an assay to be called positive, at least 2 of the 3 associated melt curves must be called positive, and the melting temperature for at least 2 of the 3 positive melt curves must be similar (within 1 degree C). Assays that do not meet these criteria are called negative.(Instruction manual: BioFire Joint Infection (JI) Panel IVD. BioFire Diagnostics, LLC; RFIT-PRT-0690-01, 06/2022)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday through Sunday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

1 to 2 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

14 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Rochester

Fees :
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

87999

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
JIP Joint Infect Panel PCR, Synovial Fl 97608-4
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
621730 CTX-M 88250-6
621731 IMP 85498-4
621732 KPC 49617-4
621733 mecA/C and MREJ (MRSA) 96309-0
621734 NDM 73982-1
621735 OXA-48-like 85827-4
621736 vanA/B 62261-3
621737 VIM 85501-5
621700 Anaerococcus prevotii/vaginalis 97609-2
621714 Bacteroides fragilis 97610-0
621729 Candida albicans 97611-8
621728 Candida spp. 97612-6
621715 Citrobacter spp. 97613-4
621701 Clostridium perfringens 97614-2
621702 Cutibacterium avidum/granulosum 97615-9
621716 Enterobacter cloacae complex 97616-7
621703 Enterococcus faecalis 97617-5
621704 Enterococcus faecium 97618-3
621717 Escherichia coli 97619-1
621705 Finegoldia magna 97620-9
621718 Haemophilus influenzae 97621-7
621719 Kingella kingae 97622-5
621720 Klebsiella aerogenes 97623-3
621721 Klebsiella pneumoniae complex 97624-1
621722 Morganella morganii 97625-8
621723 Neisseria gonorrhoeae 97626-6
621706 Parvimonas micra 97627-4
621707 Peptoniphilus spp. 97628-2
621708 Peptostreptococcus anaerobius 97629-0
621724 Proteus spp. 97630-8
621725 Pseudomonas aeruginosa 97631-6
621726 Salmonella spp. 97632-4
621727 Serratia marcescens 97633-2
621709 Staphylococcus aureus 97634-0
621710 Staphylococcus lugdunensis 97635-7
621711 Streptococcus agalactiae 97636-5
621712 Streptococcus pneumoniae 97637-3
621713 Streptococcus pyogenes 97638-1
621827 Streptococcus spp. 97639-9
621738 Interpretation 59464-8

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports

Test Update Resources

Change Type Effective Date
New Test 2024-10-01