Detection and quantitation of inhibitor to coagulation factor X
This test is not useful for the detection of a lupus-like circulating anticoagulant inhibitor, a nonspecific circulating anticoagulant, or other inhibitors that are not specific for coagulation factors.
Test Id | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
10INT | FX Inhib Profile Tech Interp | No | Yes |
F_10 | Coag Factor X Assay, P | Yes | Yes |
Test Id | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
10AIH | FX Inhib Profile Prof Interp | No | No |
10_IS | Factor X Inhib Scrn | No | No |
GBETH | General Factor Bethesda Units, P | No | No |
Testing begins with coagulation factor X activity assay with dilutions to evaluate assay inhibition; if the factor X activity assay is normal or increased, then a technical interpretation will be provided.
If the factor X activity assay is decreased, then an inhibitor screen will be performed at an additional charge to look for specific factor X inhibition and a professional interpretation will be provided. If specific inhibition is apparent, the titer of the inhibitor will be determined.
F_10, 10_IS, GBETH: Optical Clot-Based
10INT: Technical Interpretation
10AIH: Medical Interpretation
Factor X Inhibitor Screen, Plasma
Testing begins with coagulation factor X activity assay with dilutions to evaluate assay inhibition; if the factor X activity assay is normal or increased, then a technical interpretation will be provided.
If the factor X activity assay is decreased, then an inhibitor screen will be performed at an additional charge to look for specific factor X inhibition and a professional interpretation will be provided. If specific inhibition is apparent, the titer of the inhibitor will be determined.
Plasma Na Cit
This test is for factor X inhibitors only. If the presence or type of inhibitor is unknown, first order APROL / Prolonged Clot Time Profile, Plasma, except for patients with known hemophilia A or B. When screening studies are needed for patients with known hemophilia A or B, order 8INHE / Factor VIII Inhibitor Evaluation, Plasma; or 9 INHE / Factor IX Inhibitor Evaluation, Plasma; respectively.
Send all vials in the same shipping container.
Specimen Type: Platelet-poor plasma
Patient Preparation:
1. Patient must not be receiving Coumadin (warfarin) or heparin therapy
2. Fasting preferred
Collection Container/Tube: Light-blue top (3.2% sodium citrate)
Submission Container/Tube: Plastic vials
Specimen Volume: 3 mL in 3 plastic vials, each containing 1 mL
Collection Instructions:
1. Specimen must be collected prior to factor replacement therapy.
2. For complete instructions, see Coagulation Guidelines for Specimen Handling and Processing.
3. Centrifuge, transfer all plasma into a plastic vial, and centrifuge plasma again.
4. Aliquot plasma (1-2 mL per aliquot) into 3 separate plastic vials, leaving 0.25 mL in the bottom of centrifuged vial.
5. Freeze plasma immediately (no longer than 4 hours after collection) at -20 degrees C or, ideally, -40 degrees C or below.
Additional Information:
1. Double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.
2. Each coagulation assay requested should have its own vial.
If not ordering electronically, complete, print, and send a Coagulation Test Request (T753) with the specimen.
2 Plastic vials, each containing 1 mL
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | Reject |
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma Na Cit | Frozen | 14 days |
Detection and quantitation of inhibitor to coagulation factor X
This test is not useful for the detection of a lupus-like circulating anticoagulant inhibitor, a nonspecific circulating anticoagulant, or other inhibitors that are not specific for coagulation factors.
Testing begins with coagulation factor X activity assay with dilutions to evaluate assay inhibition; if the factor X activity assay is normal or increased, then a technical interpretation will be provided.
If the factor X activity assay is decreased, then an inhibitor screen will be performed at an additional charge to look for specific factor X inhibition and a professional interpretation will be provided. If specific inhibition is apparent, the titer of the inhibitor will be determined.
Coagulation factor inhibitors arise in patients who are congenitally deficient in a specific factor in response to factor replacement therapy, or they can either occur spontaneously without known cause or in response to a variety of medical conditions, including the postpartum state, immunologic disorders, certain antibiotic therapies, some malignancies, and in the older population.
Inhibitors of factor VIII coagulant activity are the most commonly occurring of the specific factor inhibitors.
FACTOR X ACTIVITY ASSAY
Adults: 70-150%
Normal, full-term newborn infants or healthy premature infants may have decreased levels (> or =15-20%) that may not reach adult levels for 180 days or more postnatal.*
*See Pediatric Hemostasis References section in Coagulation Guidelines for Specimen Handling and Processing.
FACTOR X INHIBITOR SCREEN:
Negative
GENERAL FACTOR BETHESDA UNITS:
< or =0.5 Bethesda Units
Normally, there is no inhibitor, ie, negative result.
If the screening assays indicate the presence of an inhibitor, it will be quantitated and reported in Bethesda (or equivalent) units.
Occasionally, a potent lupus-like anticoagulant may cause false-positive testing for a specific factor inhibitor (eg, factor VIII or IX).
1. Hoffman R, Benz Jr EJ, Silberstein LE, et al, eds: Hematology: Basic Principles and Practice. 7th ed. Elsevier; 2018
2. Kasper CK. Treatment of factor VIII inhibitors. Prog Hemost Thromb. 1989;9:57-86
Screening for inhibitors of specific coagulation factors is represented by the inhibitor assay for factor X. This assay consists of measuring the difference in factor X activity (prothrombin time based assay) before and after incubation of a mixture of normal plasma and patient's plasma for 1 hour at 37 degrees C. For optimal sensitivity, the factor X value of the normal plasma is adjusted to approximately 20%, because the factor X assay is more sensitive in this area of the curve. In addition, an excess of patient's plasma will make the test more sensitive to small amounts of inhibitors.(Owen CA Jr, Bowie EJW, Thompson JH Jr. The Diagnosis of Bleeding Disorders. 2nd ed. Little, Brown, and Company; 1975:143-145; Cielsa B. Defects of plasma clotting factors. In: Hematology in Practice. 3rd ed. FA Davis; 2019:chap 17)
If the inhibitor screen is positive for an inhibitor of factor X, the inhibitor will be quantitated by the "Bethesda assay." In the Bethesda procedure, inhibitors are quantified by mixing equal volumes of serially diluted plasma with normal plasma. This mixture is incubated 2 hours at 37 degrees C, and its factor X activity is measured and compared to a control run at the same time. The difference between the factor X activity of the patient's incubation mixture and that of the control is used to calculate titer. The residual factor X activity is converted to "Bethesda units": 50% residual factor X is equal to 1 Bethesda unit.(Kasper CK, Aldedort LM, Counts RB, et al. A more uniform measurement of factor VIII inhibitors. Thromb Diath Haemorrh. 1975;34:869-872; Cielsa B. Defects of plasma clotting factors. In: Hematology in Practice. 3rd ed. FA Davis; 2019:chap 17)
Monday through Friday
This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.
85390
85260
85335 (if appropriate)
85335 (if appropriate)
85390 (if appropriate)
Test Id | Test Order Name | Order LOINC Value |
---|---|---|
10INE | Factor X Inhib Profile, P | 96457-7 |
Result Id | Test Result Name |
Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
|
---|---|---|
F_10 | Coag Factor X Assay, P | 3218-5 |
10INT | FX Inhib Profile Tech Interp | 69049-5 |