Test Catalog

Test Id : FMMM

Mephedrone, MDPV and Methylone, Urine

Reflex Tests
Lists tests that may or may not be performed, at an additional charge, depending on the result and interpretation of the initial tests.

Test Id Reporting Name Available Separately Always Performed
FMMCF Mephedrone and MDPV Confirm No No
FMEYL Methylone Confirm No No

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

If the Mephedrone, MDPV, Methylone is positive, then the Mephedrone and MDPV Confirm (FMMCF) and Methylone Confirm (FMEYL) will be performed at an additional charge.

 

Positive results will reflex additional testing at an additional charge.

 

If Mephedrone and/or MDPV are positive it will reflex the Mephedrone and MDPV Confirm (FMMCF). If the Methylone is positive it will reflex the Methylone Confirm (FMEYL).

Method Name
A short description of the method used to perform the test

Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS) - Screen and Confirmation; if applicable

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Mephedrone, MDPV, Methylone

Aliases
Lists additional common names for a test, as an aid in searching

Bath Salts

Bliss

Explosion

Inpact

Ivory Wave

MDPV

Odorizer

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

If the Mephedrone, MDPV, Methylone is positive, then the Mephedrone and MDPV Confirm (FMMCF) and Methylone Confirm (FMEYL) will be performed at an additional charge.

 

Positive results will reflex additional testing at an additional charge.

 

If Mephedrone and/or MDPV are positive it will reflex the Mephedrone and MDPV Confirm (FMMCF). If the Methylone is positive it will reflex the Methylone Confirm (FMEYL).

Specimen Type
Describes the specimen type validated for testing

Urine

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Container: Preservative-free plastic urine container

Specimen volume: 10 mL

 

Collection instructions

  1. collect a random urine specimen
  2. No preservative

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.

1 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis NA
Lipemia NA
Icterus NA
Other NA

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Urine Refrigerated (preferred) 14 days
Frozen 180 days
Ambient 72 hours

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

If the Mephedrone, MDPV, Methylone is positive, then the Mephedrone and MDPV Confirm (FMMCF) and Methylone Confirm (FMEYL) will be performed at an additional charge.

 

Positive results will reflex additional testing at an additional charge.

 

If Mephedrone and/or MDPV are positive it will reflex the Mephedrone and MDPV Confirm (FMMCF). If the Methylone is positive it will reflex the Methylone Confirm (FMEYL).

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Drug                             Units                 Reference Range

-------------------------------------------------------------------------------------

Mephedrone                                          Negative

MDPV                                                  Negative

Methylone                                             Negative

 

Qualitative analysis for Mephedrone, Methylenedioxypyrovalerone (MDPV) and Methylone


Screening threshold: 1.0 ng/mL

 

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday through Sunday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

5 to 9 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Medtox Laboratories, Inc.

Fees :
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test was developed and its performance characteristics determined by LabCorp. It has not been cleared or approved by the Food and Drug Administration.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

80307-single drug

80371-(if appropriate)

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
FMMM Mephedrone, MDPV, Methylone Not Provided
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
Z3417 Mephedrone Unable to Verify
Z3418 MDPV 73687-6
Z3419 Methylone 73686-8

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports