Test Catalog

Test Id : FMNRB

Manganese, RBC and Plasma

Profile Information
A profile is a group of laboratory tests that are ordered and performed together under a single Mayo Test ID. Profile information lists the test performed, inclusive of the test fee, when a profile is ordered and includes reporting names and individual availability.

Test Id Reporting Name Available Separately Always Performed
FZ015 Manganese, Plasma No Yes
FZ016 Manganese, RBC No Yes

Method Name
A short description of the method used to perform the test

Inductively Coupled Plasma/Mass Spectrometry (ICP-MS)

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

No

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Manganese, Plasma and RBC

Aliases
Lists additional common names for a test, as an aid in searching

Mn

Specimen Type
Describes the specimen type validated for testing

Metal Free EDTA Plasma

RBCS

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Both plasma and RBCs are required for testing.

Specimen Type: Packed RBCs and Plasma

Container/Tube: Royal blue-top (EDTA metal-free tube; metal-free transfer tubes

Specimen Volume: 3 mL each of plasma and packed RBCs

Collection Instructions:  Both packed cells and plasma are required. Plasma and red cells must be separated ASAP and shipped separately. Failure to separate may cause rejection due to hemolysis of red cells and contamination of the plasma. Transfer RBCs and plasma into separate plastic, acid-washed, trace metal-free tubes. Ship refrigerated.

NOTE:  Specimen must be received at the testing facility within five days of collection.

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.

0.5 mL each plasma and RBCs

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis Reject
Other Failure to separate plasma and red cells; specimen received more than 5 days after collection.

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Metal Free EDTA Plasma Refrigerated (preferred) 5 days METAL FREE
Ambient 72 hours METAL FREE
RBCS Refrigerated (preferred) 5 days METAL FREE
Ambient 72 hours METAL FREE

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Manganese, Plasma:     <2.0 ng/mL

Manganese, RBC:         11.0 - 23.0 ng/mL

Interpretation
Provides information to assist in interpretation of the test results

Manganese is highly concentrated in the cellular elements of blood. Hemolysis of the cellular elements that is unobservable to the naked eye can result in elevated plasma manganese concentrations.

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday through Sunday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

5 to 7 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Medtox Laboratories, Inc.

Fees :
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

 83785

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
FMNRB Manganese, Plasma and RBC 87467-7
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
Z2427 Manganese, Plasma 5683-8
Z2428 Manganese, RBC 5682-0

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports