Monitoring adequacy of drug clearance during gentamicin therapy
Turbidimetric Immunoassay
Antibiotic Assay
Antimicrobial Assay
Garamycin (Gentamicin)
Gentamicin, Trough
Gentamycin
Serum
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions:
1. Serum gel tubes should be centrifuged within 2 hours of collection.
2. Red-top tubes should be centrifuged, and the serum aliquoted into a plastic vial within 2 hours of collection.
If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.
0.25 mL
Gross hemolysis | Reject |
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 7 days | |
Frozen | 14 days | ||
Ambient | 72 hours |
Monitoring adequacy of drug clearance during gentamicin therapy
Gentamicin is an antibiotic used to treat life-threatening blood infections caused by gram-negative bacilli, particularly Citrobacter freundii, Acinetobacter species, Enterobacter species, Escherichia coli, Klebsiella pneumoniae, Proteus mirabilis, Providencia stuartii, Pseudomonas aeruginosa, and Serratia species. It is often used in combination with beta-lactam therapy.
A gentamicin minimal inhibitory concentration (MIC) of 4.0 mcg/mL or less is considered susceptible for gram-negative bacilli. A MIC of 500 mcg/mL or less is considered synergistic when combined with appropriate antibiotics for treatment of serious enterococcal infections.
Conventional dosing of gentamicin is usually given 2 to 3 times per day by intravenous or intramuscular injections in doses to achieve peak blood concentration between 3.0 to 12.0 mcg/mL depending on the type of infection. Gentamicin also may be administered at higher doses (usually 5-7 mg/kg) once per day to patients with good renal function (known as pulse dosing). Dosing amount or interval must be decreased to accommodate for reduced renal function.
Ototoxicity and nephrotoxicity are the primary toxicities associated with gentamicin. This risk is enhanced in presence of other ototoxic or nephrotoxic drugs. Monitoring of serum levels and symptoms consistent with ototoxicity is important. For longer durations of use, audiology/vestibular testing should be considered at baseline and periodically during therapy.
Therapeutic: <2.0 mcg/mL
Toxic: >2.0 mcg/mL
Goal levels depend on the type of infection being treated. Goal trough levels should be less than 2.0 mcg/mL for conventional dosing. Prolonged exposure to trough levels exceeding 2.0 mcg/mL may lead to toxicity.
Patient samples that contain the drug sisomicin will yield falsely elevated values for gentamicin. However, this drug is not usually coadministered with gentamicin.
High concentrations of penicillins or cephalosporins have been shown to inactivate gentamicin in vitro. The degree of inactivation is dependent on the particular aminoglycoside being measured, the type and concentration of the penicillin or cephalosporin that is also present, and the storage conditions of the sample. For patients receiving additional antibiotics of these types, 5 to 7 samples should be assayed immediately or stored frozen.
Interfering heterophile antibodies occur at low frequency in the general population. These antibodies can cause autoagglutination of the microparticle reagent leading to undetected erroneously low results.
1. Wilson JW, Estes LL: Mayo Clinic Antimicrobial Therapy Quick Guide, 2008
2. Hammett-Stabler CA, Johns T: Laboratory guidelines for monitoring of antimicrobial drugs. Clin Chem 1998 May;44(5):1129-1140
3. Gonzalez LS III, Spencer JP: Aminoglcosides: a practical review. Am Fam Physician 1998 Nov 15;58(8):1811-1820
The assay is a homogeneous particle-enhanced turbidimetric immunoassay. The assay is based on competition between drug in the sample and drug coated onto a microparticle for antibody binding sites of the gentamicin antibody reagent. The gentamicin-coated microparticle reagent is rapidly agglutinated in the presence of the antigentamicin antibody reagent and in the absence of any competing drug in the sample. The rate of absorbance change is measured photometrically. When a sample containing gentamicin is added, the agglutination reaction is partially inhibited, slowing down the rate of absorbance change. A concentration-dependent classic agglutination inhibition curve can be obtained with maximum rate of agglutination at the lowest gentamicin concentration and the lowest agglutination rate at the highest gentamicin concentration.(Package insert: Roche Gentamicin reagent, Roche Diagnostic Corp, Indianapolis, IN 01/2018)
Monday through Sunday
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.
80170
Test Id | Test Order Name | Order LOINC Value |
---|---|---|
GENTA | Gentamicin, Trough, S | 3665-7 |
Result Id | Test Result Name |
Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
|
---|---|---|
GENTA | Gentamicin, Trough, S | 3665-7 |