Test Catalog

Test Id : LHSV

Herpes Simplex Virus (HSV), Molecular Detection, PCR, Varies

This test is only orderable for clients who send specimens directly to MCL in Jacksonville, FL. All other clients, see Rochester Test HSVPV.

Useful For
Suggests clinical disorders or settings where the test may be helpful

Aiding in the rapid diagnosis of herpes simplex virus (HSV) infections, including qualitative detection of HSV DNA in nonblood clinical specimens

 

This test should not be used to screen asymptomatic patients.

Method Name
A short description of the method used to perform the test

Real-Time Polymerase Chain Reaction (PCR)/DNA Probe Hybridization

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

No

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Herpes Simplex Virus PCR

Aliases
Lists additional common names for a test, as an aid in searching

Herpes Simplex Virus Detection by Real-Time PCR

HSV (Herpes Simplex Virus) by PCR (Polymerase Chain Reaction)

HSV Detection by Real-Time PCR

HSV PCR

LightCycler HSV

This test is only orderable for clients who send specimens directly to MCL in Jacksonville, FL. All other clients, see Rochester Test HSVPV.

Specimen Type
Describes the specimen type validated for testing

Varies

Ordering Guidance

If herpes simplex virus (HSV) is suspected in blood, order LHSVB / Herpes Simplex Virus (HSV), Molecular Detection, PCR, Blood.

 

If HSV is suspected in cerebrospinal fluid, order HSVC / Herpes Simplex Virus (HSV), Molecular Detection, PCR, Spinal Fluid.

 

If varicella-zoster virus is suspected, order LVZV / Varicella-Zoster Virus, Molecular Detection, PCR, Varies.

Necessary Information

Specimen source is required.

ORDER QUESTIONS AND ANSWERS

Question ID Description Answers
SS001 Specimen Source

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Submit only 1 of the following specimens:

 

Specimen Type: Body fluid

Sources: Pleural, peritoneal, ascites, pericardial, amniotic, or ocular

Container/Tube: Sterile container

Specimen Volume: 0.5 mL

Collection Instructions: Do not centrifuge.

 

Specimen Type: Swab

Sources: Genital, dermal, ocular, nasal, throat, or oral

Supplies: M4-RT (T605)

Container/Tube: Multimicrobe media (M4-RT)

Specimen Volume: Entire collection

Collection Instructions: Place swab back into multimicrobe media (M4-RT)

Additional Information: Source information should include main anatomical site of collection.

 

Specimen Type: Respiratory

Sources: Bronchial washing, bronchoalveolar lavage, nasopharyngeal aspirate or washing, sputum, or tracheal aspirate

Container/Tube: Sterile container

Specimen Volume: 1.5 mL

 

Specimen Type: Tissue

Sources: Brain, colon, kidney, liver, lung, etc.

Supplies: M4-RT (T605)

Container/Tube: Sterile container containing 1 mL to 2 mL of sterile saline or multimicrobe medium (M4-RT)

Specimen Volume: Entire collection

Collection Instructions: Submit only fresh tissue.

Additional Information: Source information should include main anatomical site of collection.

 

Specimen Type: Urine (<1-month old infant)

Container/Tube: Sterile container

Specimen Volume: 0.5 mL

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.

Body or Ocular Fluid: 0.4 mL

Respiratory Specimen: 1 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Calcium alginate-tipped swab
Wood swab
Transport swab containing gel
Formalin-fixed and/or paraffin-embedded tissues
Reject

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Varies Refrigerated (preferred) 7 days
Frozen 7 days

This test is only orderable for clients who send specimens directly to MCL in Jacksonville, FL. All other clients, see Rochester Test HSVPV.

Useful For
Suggests clinical disorders or settings where the test may be helpful

Aiding in the rapid diagnosis of herpes simplex virus (HSV) infections, including qualitative detection of HSV DNA in nonblood clinical specimens

 

This test should not be used to screen asymptomatic patients.

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Herpes simplex virus (HSV) types 1 and 2 are members of the Herpesviridae family and produce infections that may range from mild stomatitis to disseminated and fatal disease. Clinical conditions associated with HSV infection include gingivostomatitis, keratitis, encephalitis, vesicular skin eruptions, aseptic meningitis, neonatal herpes, genital tract infections, and disseminated primary infection.

 

Infections with HSV types 1 and 2 can differ significantly in their clinical manifestations and severity. HSV type 2 primarily causes urogenital infections and is found almost exclusively in adults. HSV type 1 is closely associated with orolabial infection, although genital infection with this virus can be common in certain populations.

 

The diagnosis of HSV infections is routinely made based on clinical findings and supported by laboratory testing using polymerase chain reaction or viral culture.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

HERPES SIMPLEX VIRUS (HSV)-1

Negative

 

HERPES SIMPLEX VIRUS (HSV)-2

Negative

 

Reference values apply to all ages.

Interpretation
Provides information to assist in interpretation of the test results

This is a qualitative assay; results are reported either as negative or positive for herpes simplex virus (HSV) type 1, HSV type 2, or HSV type indeterminate.

 

An Indeterminate result indicates that HSV DNA was detected, but the assay is unable to differentiate between HSV-1 and HSV-2. If typing is required, it is suggested that a new sample be collected for testing by an alternate method.

 

Detection of HSV DNA in clinical specimens supports the clinical diagnosis of infection due to the virus.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

A negative result does not eliminate the possibility of herpes simplex virus infection.

 

Although the reference range is typically "negative" for this assay, this assay may detect viral nucleic acid shedding in asymptomatic individuals. This may be especially relevant when dermal or genital sites are tested since intermittent shedding without noticeable lesions has been described.(1) This assay is only to be used for patients with a clinical history and symptoms consistent with HSV infection and must be interpreted in the context of the clinical picture.

Supportive Data

Accuracy/Diagnostic Sensitivity and Specificity:

To assess the accuracy of the Roche herpes simplex virus (HSV)-1/2 analyte specific reagents, clinical specimens (n=50) were tested, and the results compared to those of a laboratory-developed reference polymerase chain reaction (PCR) method.

 

Roche HSV-1/2 ASR

 

HSV-1/2 LDT

Positive

Negative

Positive

20

0

Negative

0

30

Total

20

30

 

Sensitivity (95% CI): 100% (81-100)

Specificity (95% CI): 100% (86-100)

 

Analytical Sensitivity/Limit of Detection:

The lower limit of detection of the HSV assay is 10 DNA target copies per microliter. This was established in anogenital swabs and confirmed in each specimen type accepted for this assay.

 

Analytical Specificity:

No PCR signal was obtained from extracts of 27 bacterial, viral, and fungal isolates that could be found as normal flora in sites normally tested for this organism or that could cause similar symptoms.

 

Precision:

Interassay and intra-assay precision were 100% and 100%, respectively.

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Schiffer JT, Corye L. New concepts in understanding genital herpes. Curr Infect Dis Rep. 2009;11(6):457-464

2. Espy MJ, Uhl JR, Mitchell PS, et al. Diagnosis of herpes simplex virus infections in the clinical laboratory by LightCycler PCR. J Clin Microbiol. 2000;38(2):795-799

3. Espy MJ, Ross TK, Teo R, et al. Evaluation of LightCycler PCR for implementation of laboratory diagnosis of herpes simplex virus infections. J Clin Microbiol. 2000;38(8):3116-3118

4. Sauerbrei A, Eichhorn U, Hottenrott G, Wutzler P. Virological diagnosis of herpes simplex encephalitis. J Clin Virol. 2000;17(1):31-36

5. Mitchell PS, Espy MJ, Smith TF, et al. Laboratory diagnosis of central nervous system infections with herpes simplex virus by PCR performed with cerebrospinal fluid specimens. J Clin Microbiol. 1997;35(11):2873-2877

6. Tang YW, Mitchell PS, Espy MJ, Smith TF, Persing DH. Molecular diagnosis of herpes simplex virus infections in the central nervous system. J Clin Microbiol. 1999;37(7):2127-2136

7. Schiffer JT, Corey L. Herpes simplex virus. In: Bennett JE, Dolin R, Blaser MJ, eds. Mandell, Douglas, and Bennett's Principles and Practice of Infectious Diseases. 9th ed. Elsevier; 2020:1828-1848

This test is only orderable for clients who send specimens directly to MCL in Jacksonville, FL. All other clients, see Rochester Test HSVPV.

Method Description
Describes how the test is performed and provides a method-specific reference

Viral nucleic acid is extracted by the MagNA Pure automated instrument (Roche Applied Science) from genital, dermal, tissue, or body fluid specimens. Primers directed to the DNA polymerase of herpes simplex virus (HSV) produce a 215-base pair amplicon. The LightCycler instrument (Roche Applied Science) amplifies and monitors by fluorescence the development of target nucleic acid sequences after the annealing step during PCR cycling. This is an automated polymerase chain reaction (PCR) system that can rapidly detect (30-40 minutes) amplicon development through stringent air-controlled temperature cycling and capillary cuvettes. The detection of amplified products is based on the fluorescence resonance energy transfer (FRET) principle. For FRET product detection, a hybridization probe with a donor fluorophore, fluorescein, on the 3'-end is excited by an external light source and emits light that is absorbed by a second hybridization probe with an acceptor fluorophore, LC-Red 640, at the 5'-end. The acceptor fluorophore then emits a light of a different wavelength that can be measured with a signal that is proportional to the amount of specific PCR product. LightCycler hybridization probes are designed for HSV-type 2 and sequence differences between HSV-type 2- and HSV-type 1 are detected by melting curve analysis. Melting curve analysis is performed following PCR amplification. Starting at 45 degrees C, the temperature in the thermal chamber is slowly raised to 80 degrees C, and the fluorescence is measured at frequent intervals. Sequence differences between the PCR amplification and probe melting curves are accomplished through the use of LightCycler software.(Espy MJ, Uhl JR, Mitchell PS, et al: Laboratory diagnosis of herpes simplex virus infections in the clinical laboratory by LightCycler PCR. J Clin Microbiol. 2000 Feb;38(2):795-799; Binnicker MJ, Espy MJ, Duresko B, Irish C, Mandrekar J: Automated processing, extraction and detection of herpes simplex virus types 1 and 2: A comparative evaluation of three commercial platforms using clinical specimens. J Clin Virol. 2017 Apr;89:30-33)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday through Sunday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

Same day/1 to 3 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

14 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Jacksonville

This test is only orderable for clients who send specimens directly to MCL in Jacksonville, FL. All other clients, see Rochester Test HSVPV.

Fees :
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

87529 x 2

87529 (if appropriate for government payers)

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
LHSV Herpes Simplex Virus PCR 94580-8
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
SS001 Specimen Source 39111-0
34797 HSV 1, PCR 94581-6
34798 HSV 2, PCR 94582-4

This test is only orderable for clients who send specimens directly to MCL in Jacksonville, FL. All other clients, see Rochester Test HSVPV.

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.