Identifying specific mutations within the POLE gene to assist in tumor diagnosis/classification
This test uses targeted next-generation sequencing to evaluate for somatic mutations within the POLE gene. See Targeted Genes and Methodology Details for POLE Mutation Analysis for details regarding the targeted gene regions evaluated by this test.
This test is performed to evaluate for somatic mutations within solid tumor samples. This test does not assess for germline alterations within the POLE gene.
Test Id | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
SLIRV | Slide Review in MG | No, (Bill Only) | Yes |
When this test is ordered, slide review will always be performed at an additional charge.
Sequence Capture Next-Generation Sequencing (NGS)
Next Generation Sequencing Test
NGS
Oncology Panel
Tumor Panel
POLE
When this test is ordered, slide review will always be performed at an additional charge.
Varies
Multiple oncology (cancer) gene panels are available. For more information see Hematology, Oncology, and Hereditary Test Selection Guide.
A pathology report (final or preliminary), at minimum containing the following information, must accompany specimen for testing to be performed:
1. Patient name
2. Block number-must be on all blocks, slides, and paperwork (can be handwritten on the paperwork)
3. Tissue collection date
4. Source of the tissue
This assay requires at least 20% tumor nuclei.
-Preferred amount of tumor area with sufficient percent tumor nuclei: tissue 216 mm(2)
-Minimum amount of tumor area: tissue 36 mm(2)
-These amounts are cumulative over up to 10 unstained slides and must have adequate percent tumor nuclei.
-Tissue fixation: 10% neutral buffered formalin, not decalcified
-For specimen preparation guidance, see Tissue Requirement for Solid Tumor Next-Generation Sequencing. In this document, the sizes are given as 4 mm x 4 mm x 10 slides as preferred: approximate/equivalent to 144 mm(2) and the minimum as 3 mm x 1 mm x 10 slides: approximate/equivalent to 36 mm(2).
Preferred:
Specimen Type: Tissue block
Collection Instructions: Submit a formalin-fixed, paraffin-embedded tissue block with acceptable amount of tumor tissue.
Acceptable:
Specimen Type: Tissue slide
Slides: 1 Stained and 10 unstained
Collection Instructions: Submit 1 slide stained with hematoxylin and eosin and 10 unstained, nonbaked slides with 5-micron thick sections of the tumor tissue.
Note: The total amount of required tumor nuclei can be obtained by scraping up to 10 slides from the same block.
Additional Information: Unused unstained slides will not be returned.
Specimen Type: Cytology slide (direct smears or ThinPrep)
Slides: 1 to 3 Slides
Collection Instructions: Submit 1 to 3 slides stained and coverslipped with a preferred total of 5000 nucleated cells, or a minimum of at least 3000 nucleated cells.
Note: Glass coverslips are preferred; plastic coverslips are acceptable but will result in longer turnaround times.
Additional Information: Cytology slides will not be returned.
If not ordering electronically, complete, print, and send an Oncology Test Request (T729) with the specimen.
See Specimen Required
Specimens that have been decalcified (all methods) Specimens that have not been formalin-fixed, paraffin-embedded, except for cytology slides Extracted nucleic acid (DNA/RNA) | Reject |
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Ambient (preferred) | ||
Refrigerated |
Identifying specific mutations within the POLE gene to assist in tumor diagnosis/classification
This test uses targeted next-generation sequencing to evaluate for somatic mutations within the POLE gene. See Targeted Genes and Methodology Details for POLE Mutation Analysis for details regarding the targeted gene regions evaluated by this test.
This test is performed to evaluate for somatic mutations within solid tumor samples. This test does not assess for germline alterations within the POLE gene.
When this test is ordered, slide review will always be performed at an additional charge.
This test uses formalin-fixed paraffin-embedded tissue or cytology slides to assess for mutations involving the POLE gene known to be associated with a variety of tumor types, including endometrial, ovarian, lung, and colorectal cancers, and diffuse glioma. POLE (exonuclease domain) alterations are typically associated with ultramutated tumors with a high tumor mutation burden and may occur as a part of constitutional replication repair deficiency syndrome.
An interpretive report will be provided.
The interpretation of molecular biomarker analysis includes an overview of the results and the associated diagnostic, prognostic, and therapeutic implications.
This test cannot differentiate between somatic and germline alterations. Additional testing may be necessary to clarify the significance of results if there is a potential hereditary risk.
DNA variants of uncertain significance may be identified.
A negative result does not rule out the presence of a variant that may be present below the limits of detection of this assay. In a specimen with 20% or more tumor content, the analytical sensitivity of this assay for sequence reportable alterations is 5% mutant allele frequency with a minimum coverage of 500X.
Point mutations and small deletion-insertion mutations will be detected in the POLE gene only. This test may detect single exon deletions but does not detect multi-exon deletions, duplications, or genomic copy number variants.
Variant allele frequency (VAF) is the percentage of sequencing reads supporting a specific variant divided by the total sequencing reads at that position. In somatic testing, VAF should be interpreted in the context of several factors including, but not limited to, tumor purity/heterogeneity/copy number status (ploidy, gains/losses, loss of heterozygosity) and sequencing artifact/misalignment.(1,2)
Rare alterations (ie, polymorphisms) may be present that could lead to false-negative or false-positive results.
Test results should be interpreted in the context of clinical, tumor sampling, histopathological, and other laboratory data. If results obtained do not match other clinical or laboratory findings, contact the laboratory for discussion. Misinterpretation of results may occur if the information provided is inaccurate or incomplete.
Reliable results are dependent on adequate specimen collection and processing. This test has been validated on cytology slides and formalin-fixed, paraffin-embedded tissues; other types of fixatives are discouraged. Improper treatment of tissues, such as decalcification, may cause polymerase chain reaction failure.
Performance Characteristics:
The limit of detection for calling a somatic variant (single nucleotide variants [SNV] and deletions/insertions [delins, formerly indel]) is 5% variant allele frequency and having at least 500x deduplicated coverage.
Verification studies demonstrated concordance between this test and the reference method for detection of SNV and delins is 98.5% (673/683) and 98.4% (122/124) of variants, respectively. Concordance for the detection of delins was 99.0% (100/101) in variants 1 to 10 base pairs (bp) in size, 93.3% (14/15) in variants 11 to 50 bp in size, and 100% (8/8) in variants over 50 bp in size.
To ensure accuracy, this test will be performed on cases that are estimated by a pathologist to have at least 20% tumor cells.
1. Strom SP. Current practices and guidelines for clinical next-generation sequencing oncology testing. Cancer Biol Med. 2016;13(1):3-11. doi:10.28092/j.issn.2095-3941.2016.0004
2. Spurr L, Li M, Alomran N, et al. Systematic pan-cancer analysis of somatic allele frequency. Sci Rep. 2018;8(1):7735. Published 2018 May 16. doi:10.1038/s41598-018-25462-0
3. Cancer Genome Atlas Network: Comprehensive molecular characterization of human colon and rectal cancer. Nature. 2012;487(7407):330-337
4. Church DN, Briggs SE, Palles C,et al: DNA polymerase e and d exonuclease domain mutations in endometrial cancer. Hum Mol Genet. 2013;22(14):2820-8
5. Hoang LN, McConechy MK, Kobel M, et al. Polymerase Epsilon Exonuclease Domain Mutations in Ovarian Endometrioid Carcinoma. Int J Gynecol Cancer. 2015;25(7):1187-1193
6. Palles C, Cazier JB, Howarth KM,et al: Germline mutations affecting the proofreading domains of POLE and POLD1 predispose to colorectal adenomas and carcinomas. Nat Genet. 2013;45(2):136-144
7. Rohlin A, Zagoras T, Nilsson Set al. A mutation in POLE predisposing to a multi-tumour phenotype. Int J Oncol. 2014;45(1):77-81
8. Jumaah AS, Salim MM, Al-Haddad HS, et al: The frequency of POLE-mutation in endometrial carcinoma and prognostic implications: a systemic review and meta-analysis. J Pathol Transl Med. 2020;54(6):471-479
9. Wu Q, Zhang N, Xie X: The clinicopathological characteristics of POLE-mutated/ultramutated endometrial carcinoma and prognostic value of POLE status: a meta-analysis based on 49 articles incorporating 12,120 patients. BMC Cancer. 2022;22(1):1157
10. Leon-Castillo A, Britton H, McConechy MK, et al: Interpretation of somatic POLE mutations in endometrial carcinoma. J Pathol. 2020;250(3):323-335
Next-generation sequencing is performed to evaluate the presence of a mutation in all coding regions of the POLE gene. See Targeted Genes and Methodology Details for POLE Mutation Analysis for details regarding the targeted gene regions identified by this test.(Unpublished Mayo method)
A pathology review and macro dissection to enrich for tumor cells is performed prior to slide scraping.
Monday through Friday
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.
88381-Microdissection, manual
81479
Test Id | Test Order Name | Order LOINC Value |
---|---|---|
POLET | POLE Mutation Analysis, Tumor | 105597-9 |
Result Id | Test Result Name |
Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
|
---|---|---|
619677 | Result | 82939-0 |
619678 | Interpretation | 69047-9 |
619679 | Additional Information | 48767-8 |
619680 | Specimen | 31208-2 |
619681 | Tissue ID | 80398-1 |
619682 | Method | 48767-8 |
619683 | Disclaimer | 62364-5 |
619684 | Released By | 18771-6 |
Change Type | Effective Date |
---|---|
New Test | 2023-07-11 |