Test Catalog

Test Id : DCORT

11-Deoxycortisol, Serum

Useful For
Suggests clinical disorders or settings where the test may be helpful

Diagnostic workup of patients with congenital adrenal hyperplasia

 

Part of metyrapone testing in the workup of suspected secondary or tertiary adrenal insufficiency

 

Part of metyrapone testing in the differential diagnostic workup of Cushing syndrome

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

For more information see Steroid Pathways.

Method Name
A short description of the method used to perform the test

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

11-Deoxycortisol, S

Aliases
Lists additional common names for a test, as an aid in searching

11-Deoxycortisol

11-Deoxycorticosteroid

Cortodoxone

INN

USAN

BAN

11-Desoxycortisol

17-hydroxy-11-deoxycorticosterone

Compound B

Compound S

Corticosterone

Deoxycortisol

Tetrahydro S

Cortoxelone

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

For more information see Steroid Pathways.

Specimen Type
Describes the specimen type validated for testing

Serum

Necessary Information

Indicate if specimen was collection before or after metyrapone administration.

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions:

1. Morning (8 a.m.) specimen is preferred.

2. Centrifuge and aliquot serum into a plastic vial.

Special Instructions
Library of PDFs including pertinent information and forms related to the test

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.

0.4 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Gross hemolysis Reject
Gross lipemia OK
Gross icterus OK

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 28 days
Ambient 28 days
Frozen 28 days

Useful For
Suggests clinical disorders or settings where the test may be helpful

Diagnostic workup of patients with congenital adrenal hyperplasia

 

Part of metyrapone testing in the workup of suspected secondary or tertiary adrenal insufficiency

 

Part of metyrapone testing in the differential diagnostic workup of Cushing syndrome

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

For more information see Steroid Pathways.

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

11-Deoxycortisol (compound S) is the immediate precursor of cortisol:

 

                           11 beta-hydroxylase

11-deoxycortisol--------------------------->cortisol

 

Compound S is typically increased when corticotropin (previously adrenocorticotropic hormone: ACTH) levels are increased (eg, Cushing disease, ACTH-producing tumors) or in 11-beta-hydroxylase deficiency, a rare subform of congenital adrenal hyperplasia (CAH). In CAH due to 11-beta-hydroxylase deficiency, cortisol levels are low, resulting in increased pituitary ACTH production and increased serum and urine 11-deoxycortisol levels.

 

Pharmacological blockade of 11-beta-hydroxylase with metyrapone can be used to assess the function of the hypothalamic-pituitary-adrenal axis (HPA). In this procedure, metyrapone is administered to patients, and serum 11-deoxycortisol levels or urinary 17-hydroxy steroid levels are measured either at baseline (midnight) and 8 hours later (overnight test), or at baseline and once per day during a 2-day metyrapone test (4-times a day metyrapone administration over 2 days). Two-day metyrapone testing has been largely abandoned because of the logistical problems of multiple timed urine and blood collections and the fact that overnight testing provides very similar results. In either case, the normal response to metyrapone administration is a fall in serum cortisol levels, triggering a rise in pituitary ACTH secretion, which, in turn, leads to a rise in 11-deoxycortisol levels due to the ongoing 11-deoxycortisol-to-cortisol conversion block.

 

In the diagnostic workup of suspected adrenal insufficiency, the results of overnight metyrapone testing correlate closely with the gold standard of HPA-axis assessment, insulin hypoglycemia testing. Combining 11-deoxycortisol measurements with ACTH measurements during metyrapone testing further enhances the performance of the test. Impairment of any component of the HPA-axis results in a subnormal rise in 11-deoxycortisol levels. By contrast, standard-dose or low-dose ACTH(1-24) (cosyntropin)-stimulation testing, which forms the backbone for diagnosis of primary adrenal failure (Addison disease), only assess the ability of the adrenal cells to respond to ACTH stimulation. While this allows unequivocal diagnosis of primary adrenal failure, in the setting of secondary or tertiary adrenal insufficiency, metyrapone testing is more sensitive and specific than either standard-dose or low-dose ACTH(1-24)-stimulation testing.

 

Metyrapone testing is also sometimes employed in the differential diagnosis of Cushing syndrome. In Cushing disease (pituitary-dependent ACTH overproduction), the ACTH-hypersecreting pituitary tissue remains responsive to the usual feedback stimuli, just at a higher "set-point" than in the normal state, resulting in increased ACTH secretion and 11-deoxycortisol production after metyrapone administration. By contrast, in Cushing syndrome due to primary adrenal corticosteroid oversecretion or ectopic ACTH secretion, pituitary ACTH production is appropriately shut down, and there is usually no further rise in ACTH and, hence 11-deoxycortisol, after metyrapone administration. The metyrapone test has similar sensitivity and specificity to the high-dose dexamethasone suppression test in the differential diagnosis of Cushing disease but is less widely used because of the lack of availability of an easy, automated 11-deoxycortisol assay. In recent years, both tests have been supplanted to some degree by corticotropin-releasing hormone (CRH)-stimulation testing with petrosal sinus serum ACTH sampling.

 

For more information see Steroid Pathways.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

< or =18 years: <344 ng/dL

>18 years: 10-79 ng/dL

 

For International System of Units (SI) conversion for Reference Values, see www.mayocliniclabs.com/order-tests/si-unit-conversion.html.

Interpretation
Provides information to assist in interpretation of the test results

In a patient suspected of having congenital adrenal hyperplasia (CAH), elevated serum 11-deoxycortisol levels indicate possible 11-beta-hydroxylase deficiency. However, not all patients will show baseline elevations in serum 11-deoxycortisol levels. In a significant proportion of cases, increases in 11-deoxycortisol levels are only apparent after corticotropin (previously adrenocorticotropic hormone)(1-24) stimulation.(1)

 

Serum 11-deoxycortisol levels below 1700 ng/dL when measured 8 hours after metyrapone administration is indicative of probable adrenal insufficiency. The test cannot reliably distinguish between primary and secondary or tertiary causes of adrenal failure, as neither patients with pituitary failure, nor those with primary adrenocortical failure, tend to show an increase of 11-deoxycortisol levels after metyrapone is administered.

 

For more information see Steroid Pathways.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

Ethanol, estrogens (exogenous and pregnancy-related), barbiturates, valproic acid, phenytoin, and exogenous glucocorticoids may cause impaired response to metyrapone.

 

There have been occasional reports of addisonian crisis during 2-day metyrapone testing. For this reason, 2-day metyrapone testing probably should not be performed when plasma cortisol values are less than 3 mcg/dL.

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Tonetto-Fernandes V, Lemos-Marini SH, Kuperman H, et al. Serum 21-deoxycortisol, 17-hydroxyprogesterone, and 11-deoxycortisol in classic congenital adrenal hyperplasia: clinical and hormonal correlations and identification of patients with 11 beta-hydroxylase deficiency among a large group with alleged 21-hydroxylase deficiency. J Clin Endocrinol Metab. 2006;91(6):2179-2184

2. Lashanske G, Sainger P, Fishman K, et al. Normative data for adrenal steroidogenesis in a healthy pediatric population: age- and sex-related changes after adrenocorticotropin stimulation. J Clin Endocrinol Metab. 1991;73(3):674-686

3. Holst JP, Soldin SJ, Tractenberg RE, et al. Use of steroid profiles in determining the cause of adrenal insufficiency. Steroids. 2007;72(1):71-84

4. Berneis K, Staub JJ, Gessler A, et al. Combined stimulation of adrenocorticotropin and compound-S by single dose metyrapone test as an outpatient procedure to assess hypothalamic-pituitary-adrenal function. J Clin Endocrinol Metab. 2002;87(12):5470-5475

5. Idkowiak, J, Cragun, D, Hopkin RJ, Arlt W. Cytochrome P450 oxidoreductase deficiency. In: Adam MP, Feldman J, Mirzaa GM, et al, eds. Gene Reviews [Internet]. University of Washington, Seattle; 2005. Updated August 3, 2017. Accessed May 2, 2024. Available at www.ncbi.nlm.nih.gov/sites/books/NBK1419/

6. Held PK, Bird IM, Heather NL. Newborn screening for congenital adrenal hyperplasia: review of factors affecting screening accuracy. Int J Neonatal Screen. 2020;6(3):67. doi:10.3390/ijns6030067

Method Description
Describes how the test is performed and provides a method-specific reference

The specimen and an internal standard are assayed by liquid chromatography tandem mass spectrometry. The analyte is detected by multiple-reaction monitoring.(Unpublished Mayo method)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Tuesday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

3 to 10 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

14 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Rochester

Fees :
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

82634

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
DCORT 11-Deoxycortisol, S 1657-6
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
46923 11-Deoxycortisol, S 1657-6

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports